Liberty Blue Microwave Peptide Synthesizer
Liberty Blue Microwave Peptide Synthesizer Peptide synthesis made fast and efficient
CEM is transforming the way chemists perform peptide synthesis once again with the introduction of the Liberty Blue™ Microwave Peptide Synthesizer. More than just a facelift, the Liberty Blue System has been designed for maximized speed and effi ciency. With a 4-minute cycle time and a 90% reduction in solvent consumption, no other peptide synthesizer on the market can even come close to the performance of the Liberty Blue. Unparalleled peptide quality, greater fl exibility, and improved reliability make Liberty Blue the system of choice for all your peptide synthesis needs.
Remarkably fast
- Rapid reagent addition
- Optimized synthesis methods
- >80% time reduction compared to 1st generation microwave synthesizers
- Difficult peptides such as A-beta in hours rather than days
The 4-minute cycle time of the Liberty Blue System is not limited to easily synthesized peptides. These methods can be used to routinely synthesize a wide range of peptides. Using the standard Liberty Blue methods, A-beta 1-42 was prepared in less than 4 hours in 68% crude purity.
- 4-minute cycle time
- 90% solvent reduction
Maximum efficiency
- Up to 90% solvent reduction
- Less reagent usage
- No priming required
- Judicious use of solvent for washing
- Accurate and precise reagent addition
Benefits of microwave control
Liberty Blue offers several advantages over alternative heating methods. The microwave energy can be controlled for each step, and the reaction temperature can be carefully selected depending on the specific peptide and/or reagents used. CEM is the only microwave provider than can apply the microwave energy to the entire process. Microwave irradiation heats the reaction from the inside rather than the outside making it possible to rapidly change the temperature from one stage to the
next. This can be especially important when synthesizing peptides containing temperature-sensitive amino acids, such as phosphopeptides, or peptides containing difficult to couple residues such as Aib. The synthesis of the double Aib containing peptide below was performed with the coupling of the second Aib residue at both 75 °C and at 95 °C with all of the rest of the conditions the same. The coupling at 75 °C resulted in only 44% crude purity with a significant Aib deletion while the 95 °C
gave 90% crude purity.
- Flexibility
- Cleavage option
- Amino Acid Bottles
- Reaction Vessels
- Fiber Optic
- Microwave
- Solvent Resistant Composite Covers
- Waste Level Detection
- Compact Footprint
- LED Lights
Flex-Add Technology
Flex-Add Technology Liberty Blue’s patent-pending Flex-Add Technology is a new approach to reagent addition that utilizes pressure to measure reagent volume. The Flex-Add Technology is both accurate and precise over a large volume range, allowing for both small and large scale syntheses to be performed on the system seamlessly.
- Simplicity
- Reliability
- Liberty Blue Software
Options for the Liberty Blue System
UV Monitoring
Resin Loader
Cleavage option
Increased Purity of Diffi cult Sequences
The Microwave Advantage
Microwave energy directly couples at the molecular level with polar and ionic species. The movement of the molecules trying to align themselves with the electric field of the microwave causes motion, and thus, produces heat. However, it is this transfer of kinetic energy that makes all of the difference in microwave peptide synthesis. The constant realignment of the peptide chain in the microwave field accelerates the reaction and helps to keep it from aggregating, significantly improving results of the synthesis.
- License included with each system allowing the use of microwave energy for both the coupling and deprotection steps
- Fastest cycle times available
- Unparalleled peptide purity and yield compared to conventional synthesis
- Significantly reduces purification time and waste
- Access to peptides impossible to synthesize under conventional conditions
SPECIFICATIONS
Synthesis Scale 0.025 – 5 mmol
Reaction Vessel Sizes 10-, 30- and 125-mL standard
Chemistry Fmoc only
Activation Method In situ, standard activators
Amino Acid Reagents 20, plus 7 additional positions
External Bottle Positions 2, plus 7 additional positions
Temperature Measurement In situ fi ber-optic
Fluid Measurement Flex-Add – amino acids, activator, activator base Timed delivery – Main wash, Deprotection
Agitation Programmable inert gas bubbling
Waste Container 1 L reservoir with overfl ow detection
Controller Laptop with wireless option standard
Optional Features UV monitor
Resin Loader for high throughput
Cleavage module
Reports Printable .pdf fi le for each method created. Log created during each run of every step performed
Power 120V/60Hz or 240V/50Hz
Dimensions 20”W x 18”D x 30”H
(51 cm x 46 cm x 76 cm)