MARS 6 Microwave Reaction System
CEM brings a remarkable intelligence and ease of use to microwave sample preparation with the new MARS 6 System. Totally redesigned with an impressive list of features and capabilities, MARS 6 was developed to make microwave sample preparation virtually effortless.
Versatility
The MARS 6 is incredibly versatile and can be configured for digestion, extraction, or both. It can also perform a variety of other chemistries including parallel or batch synthesis, protein hydrolysis, and evaporation / concentration.
MARS 6 was developed to make microwave sample preparation virtually effortless.
- Choose from simple CEM One Touch™ Technology* or MARS Classic method programming
- Dual magnetrons - more power delivery than any other microwave digestion system
- PowerMAX power control technology delivers optimum energy to the sample for more complete digestions
- Large (7”) wide-format, high-resolution, acid-resistant touch screen – no external controllers needed
- Remarkably easy-to-use, intuitive on-board software
- Advanced sensor technology for vessel recognition, temperature and pressure control
- Improved connectivity – 6 USB ports and 2 Ethernet ports allow connections to multiple peripherals such as keyboards, printers, computers, or a laboratory network system
Features
- HIGH-RESOLUTION, FULL COLOR TOUCHSCREEN WITH SPEAKERS- Large 7” (800 x 480) glass capacitive LED screen serves as controller and display
- 8-GIGABYTE ONBOARD CONTROLLER - No need for a laptop or external controller
- POWERMAX™ POWER CONTROL - Delivers maximum energy to the sample, ensuring complete digestions
- ONE TOUCH OR MARS CLASSIC METHOD PROGRAMMING - Select which program is best for you
- ACID- AND IMPACT-RESISTANT COMPOSITE SHELL - Better system protection in a laboratory
- environment than a metal wrap
- I/O PORT - Standard 0.500” I.D. port or optional 0.3125” I.D. ports for 6mm tubing allows for introduction of multiple components into the cavity
- METHOD LIBRARY - Pre-loaded with USEPA and other internationally recognized methods
- DATA AT A GLANCE - Touchscreen interface provides easy access to stored methods, real-time
- data, results of past runs, and training videos
- CONNECTIVITY Available ports: 5 USB, 1 USB-B, 2 Ethernet, and1 RS-232
- TOUCHSCREEN TRAINING VIDEOS - Learn more about your system, how to use different vessel sets and options, and running samples right on the MARS 6.
- INTEGRATED PRINTER - Print graphs and data for documentation
PowerMAX
- Automatic Power Control
- 1800 Watts of Delivered Microwave Energy
- Wave Guide Power Delivery Ensures Microwave Uniformity
- DuoTemp Control- DuoTemp & MARSXpress DuoTemp - All Vessel Temperature Control
- Sensors And Controls
- Direct Fiber Optic Temperature Sensor of the Reference Vessel
- Single Vessel Reference Pressure Sensor
- Contactless Pressure Sensor
- Contactless All-Vessel Temperature Sensors
ONE TOUCH Feature
- One Touch Methods
- One Touch Sensor Technology
- One Touch Vessel Technology
- One Touch Sample & Vessel Preparation Technology
PowerMAXTM
- Automatic Power Control
- 1800 Watts of Delivered Microwave Energy
- Wave Guide Power Delivery Ensures Microwave Uniformity
- DuoTemp & MARSXpress DuoTemp All Vessel Temperature Control
SENSORS AND CONTROLS
- Direct Fiber Optic Temperature Sensor of the Reference Vessel
- Single Vessel Reference Pressure Sensor
- Contactless Pressure Sensor
- Contactless All-Vessel Temperature Sensors
SPECIFICATIONS
Overall Instrument Dimensions 63.5 cm (25 in.) height x 53.3 cm (21 in.) width X 63.5 cm (25 in.) depth
Weight 63.6 kg (140 lbs.)
Touchscreen 7” (800 x 480) TFT-LED glass capacitive touchscreen display
One Touch A combination of vessel recognition and vessel counting sensor technology, software technology, and applications knowledge that enables a user to select a One Touch method that matches their sample type. Based on the sample type, One Touch Technology determines the vessel type and count, digestion temperature, ramp and hold times, and microwave power input.
PowerMAX Power control technology provides the maximum amount of energy to the sample to ensure complete digestions.
Ports 5 USB, 2 Ethernet, 1 USB-B, 1 RS-232
Sensors All sensors, including pressure and temperature sensing devices located within the microwave cavity, are microwave-transparent or shielded to ensure accurate readings and to eliminate arcing (ignition) hazards.
Languages Software available in English, German, French, Italian, Spanish, Chinese, and Japanese.
Sample Stirring In-vessel magnetic stirring of samples at three levels of speed.
Turntable Design PerfectCircle™ design provides absolute radial symmetry. Turntable operates in alternating or continuous mode.
Door Lock An optional software controlled solenoid lock is engaged to lock the door at the beginning of a digestion run and automatically unlocks after the digestion run at a user defi ned temperature.
Inlet/Outlet Ports Standard 0.500” I.D. port or optional 0.3125” I.D. ports for 0.250” (6mm) tubing
Microwave Cavity Heavy-duty, multi-layer Tefl on® coating
Electrical Requirements 200/208/230 VAC (200-253 VAC), 60 Hz, 15A @ 230 VAC
220/240 VAC (202-250 VAC), 50 Hz, 15A @ 240 VAC
Magnetron Frequency 2450 MHz
Power Output 1800 W – Continuous power available at all power levels to provide more control for reactions. (IEC 705 Method – 1988)
Magnetron Protection Solid-state isolator (US patent 4,835,354) to protect magnetron from refl ected energy, ensuring constant power output.
Speakers 8 Ω, 2 W, 86 dB
Printer Onboard thermal printer and USB-B compatible printer port
Safety Features Three independent door safety interlocks, including an interlock monitoring system plus three independent thermal switches, are used in each instrument to prevent instrument operation and microwave emissions in case of improper door closure or misalignment. The instrument complies with HHS standards under 21 CFR, Part 1030.10, Subparts (C)(1), (C)(2) and (C)(3). Reactiguard continuously monitors the cavity and disables the magnetron if disturbances occur inside the cavity.
Emissions and Safety Approvals Conforms to Globally Harmonized EN61010-1 Standard for Safety Requirements for Electric Equipment for Measurement, Control, and Laboratory Use Part 1: General Requirements (CAN/CSA-C22.2 No. 1010.1- 1992).