STAR Rapid Open Vessel Sample Preparation

Though, the STAR System is designed for convenience and flexibility, freeing the analyst from the time-consuming tasks involved in sample preparation. The STAR System automatically adds reagent to the vessels according to the requirements of the programmed method. The reagent is added in aliquots while the digestion is running to prevent cooling the digestate. The system’s proprietary pump technology ensures that an accurate measurement of reagent is delivered instantaneously on demand. Each reagent has a dedicated pump for every cell eliminating any mixing or cross contamination of reagents.

Simplify Problem Digestions!

Plastics

Oils

Polymers

Foods

Filters ( i.e., Toray)

Sulfuric Acid Reduction

Plant/Animal Tissue

 

System Specifications (each 2 place reactor)

 

 

                                                              STAR System

Dimensions (WxDxH),                         18 x 13.15 x 14 in

Main Microwave Unit                            45.72 x 33.4 x 35.5 cm

Dimensions (WxDxH),                          6.5 x 9 x 12 in

Vapor Containment/                              6.54 x 22.86 x 30.48 cm

Reagent Addition Module

Weight                                                   48 lbs (21.77 kg)

(microwave unit only)

Power Requirements                            120 ± 10% VAC, 60V Hz

(separate line recommended)               220/240 ± 10% VAC, 50 Hz

Program Storage                                   20 methods

Operating Temperature                         Ambient - 500 °C

Readout Temperature                           Ambient - 430 °C

Temperature Control                             Individual sample feedback per cavity

Sensors, Temperature                           2

Sensors, Vessel-in-Position                   2

Sensors, Arm-in-Position                       2

Vessel Capacity                                    250, 100, 50mL

Number of Vessels Per Unit                   Maximum 2

Number of Simultaneously                     Maximum 2

Run Programs

Number of Staggered                            Maximum 2

Start Times

Vapor Containment Module                    Standard

Automatic Reagent Addition *                 Maximum of four reagents per pump module

Maximum of five pump modules per instrument

Automatic Vacuum                                  Optional

Pump Switch

Keypad Type                                          Membrane

Printer Port                                             Parallel